Rotarex in the UK, Authorised Distributor and Stockist

Southern CGS is an authorised UK distributor and stockist for Rotarex, the Luxembourg manufacturer of specialty gas control equipment. Rotarex has made cylinder valves, pressure regulators and gas systems since 1922 and its ultra high purity range is assembled, tested and packaged for the semiconductor, analytical and pharmaceutical gas systems that cannot tolerate contamination from the equipment itself.

We hold Rotarex stock in the UK and supply the ranges that UK laboratories, gas installers, OEMs and process sites actually order: the RX series UHP regulators, the S series and Mono series low pressure and laboratory regulators, single and dual stage cylinder regulators, manual and automatic changeover manifolds, tied diaphragm and bellows line valves, and industrial, high purity and UHP cylinder valves.

Every Rotarex product we carry has its own page below with the specification, and where a decision needs more than a spec table, ask us. We will tell you which unit fits your gas, pressure and purity grade, and if the answer is a different product, we will say so.

Showing 69 products

All Rotarex

Regulators (Rotarex)

31 products
Series CEN Autochange Manifold - Gas Manifolds by Southern CGS

Gas Manifolds

Series CEN Autochange Manifold

Auto-change manifold offering high flow supply of non-corrosive industrial gases. Balanced valve technology removes the requirement for secondary regulation downstream.

CMI Manual Manifold - Gas Manifolds by Southern CGS

Gas Manifolds

Series CMI Manifold

Supply board with duo bloc single stage diaphragm technology. Regulator technology designed for corrosive gases.

Valves (Rotarex)

35 products
D304 High pressure 4mm orifice Valve - Ultra high purity tied diaphragm seal type by Southern CGSD304 High pressure 4mm orifice Valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D304 High pressure 4mm orifice Valve

D304 valve for UHP, corrosive, reactive and toxic gases from Rotarex Puretec is designed for keeping the highest level of purity of the gas. No particles are generated in the gas wetted part thanks to the tied diaphragm technology. It is also available with the new Open/close indicator from Rotarex Puretec

D385S High Pressure Pneumatic Valve soft seat 4mm orifice - Ultra high purity tied diaphragm seal type by Southern CGSD385S High Pressure Pneumatic Valve soft seat 4mm orifice - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D385S High Pressure Pneumatic Valve soft seat 4mm orifice

D385S valve with pneumatic actuator is designed for keeping the highest level of purity of the gas. Its tied diaphragm technology allows to avoid any particle generation. The D385S is used for UHP, corrosive, reactive and toxic gases, common in the electronic and semicondutor industry.

Residual Pressure Valve - RPV Valves by Southern CGSResidual Pressure Valve - RPV Valves by Southern CGS

RPV Valves

Residual Pressure Valve

The Residual Pressure Device prevents ingress of contaminants like moisture and particles in the cylinder and ensures a longer life time of the cylinder.

D386S Tied diaphragm cylinder valve for fluorine mixtures with pneumatic actuator - Ultra high purity tied diaphragm seal type by Southern CGSD386S Tied diaphragm cylinder valve for fluorine mixtures with pneumatic actuator - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D386S Tied diaphragm cylinder valve for fluorine mixtures with pneumatic actuator

The D386S ensures the highest levels of purity and safety for applications using fluorine gas mixtures, such as cleaning non-plasma deposition chambers and diffusion furnaces for silicon-based films. Designed with the challenges of fluorine-nitrogen mixtures in mind, this UHP cylinder valve incorporates specialized features to enhance operational safety and maintain the purity of F₂/N₂ mixtures, supporting contamination-free manufacturing

D354 Oleo-Pneumatic Soft seat 4mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGSD354 Oleo-Pneumatic Soft seat 4mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D354 Oleo-Pneumatic Soft seat 4mm orifice valve

D354 valve with oleo-pneumatic actuator is designed for keeping the highest level of gas purity. No particle are generated thanks to its tight diaphragm technology. Commonly used for ultra-high-purity, corrosive, reactive and toxic gases, its oleo-pneumatic actuator increase the seat closure force.

D340S Dual Port UHP valve Soft seat 4mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGSD340S Dual Port UHP valve Soft seat 4mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D340S Dual Port UHP valve Soft seat 4mm orifice valve

D340S valve for Ultra-High Purity gases from Rotarex Puretec is designed for keeping the highest level of purity of the gas. The dual port technology ease withdrawal of liquefied gas by pressurizing through vapour port. No particles are generated in the gas wetted part thanks to the tied diaphragm technology.

K300 Bellows Valve - HP & UHP Gas Valves by Southern CGS

High-Performance bellows Valves for cryogenic gases and liquids

K300 Bellows Valve

Low or high pressure bellows valve. Operating range -40°C to +120°C ambient.

D306 High pressure Metal / Metal sealing 3.5mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGSD306 High pressure Metal / Metal sealing 3.5mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D306 High pressure Metal / Metal sealing 3.5mm orifice valve

D306 cylinder valve for Ultra High Purity highly oxidizing and reactive gases is designed for keeping the highest level of gas purity, thanks to its tied diaphragm technology. The Rotarex Puretec D306 UHP cylinder valve is also available with the new Open/close indicator.

HP2000 Bellows Valve - HP & UHP Gas Valves by Southern CGS

High-Performance bellows Valves for cryogenic gases and liquids

HP2000 Bellows Valve

High pressure bellows valve. Operating range -40°C to +120°C ambient.

D356 Oleo-pneumatic valve Metal / Metal sealing 3.5mm orifice - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D356 Oleo-pneumatic valve Metal / Metal sealing 3.5mm orifice

The D356 UHP cylinder valve with oleo-pneumatic actuator is designed for Ultra High Purity highly oxidizing and reactive gases, ensuring the highest level of gas purity thanks to its tied diaphragm technology. Its oleo-pneumatic actuator increases the seat closure force for maximum safety.

K900 Bellows Valve - HP & UHP Gas Valves by Southern CGS

High-Performance bellows Valves for cryogenic gases and liquids

K900 Bellows Valve

Low to high pressure bellows valve. Operating range -196°C to +250°C cryogenic.

D339S High pressure manual valve Soft seat 6mm orifice - Ultra high purity tied diaphragm seal type by Southern CGSD339S High pressure manual valve Soft seat 6mm orifice - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D339S High pressure manual valve Soft seat 6mm orifice

D339S valve is designed for keeping the highest level of purity of UHP, corrosive, reactive and toxic gases. No particles are generated in the gas wetted part thanks to the tied diaphragm technology. The D339S is also available with the new Open/close indicator from Rotarex Puretec.

HP9000 Bellows Valve - HP & UHP Gas Valves by Southern CGS

High-Performance bellows Valves for cryogenic gases and liquids

HP9000 Bellows Valve

High pressure bellows valve. Operating range -196°C to +250°C cryogenic.

D389S Oleo-Pneumatic Soft seat 6mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D389S Oleo-Pneumatic Soft seat 6mm orifice valve

D389S UHP cylinder is designed for keeping the highest level of purity of the gas. The seat closure force is increased thanks to its oleo-pneumatic actuator. The tight diaphragm technology allows no particle are generation in the gas wetted parts.

HP3000 Bellows Valve - HP & UHP Gas Valves by Southern CGS

High-Performance bellows Valves for cryogenic gases and liquids

HP3000 Bellows Valve

High pressure bellows valve. Operating range -40°C to +120°C ambient.

D349 Dual Port UHP valve Soft seat 6mm orifice - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D349 Dual Port UHP valve Soft seat 6mm orifice

D349 valve for UHP gases is designed for keeping the highest level of purity of the gas. Easy withdrawal of liquefied gas thanks to the dual port technology. The D349 allows a high flow value at high pressure with its 6mm orifice size.

Supra Bellows Valve - HP & UHP Gas Valves by Southern CGS

High-Performance bellows Valves for cryogenic gases and liquids

Supra Bellows Valve

Low pressure bellows valve. Operating range -270°C to +80°C cryogenic.

D337 Tied-diaphragm seal Low Pressure 8mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGSD337 Tied-diaphragm seal Low Pressure 8mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D337 Tied-diaphragm seal Low Pressure 8mm orifice valve

D337 low pressure manual cylinder valve for Ultra High Purity, corrosive, reactive and toxic gases is designed for keeping the highest level of purity of the gas, thanks to the tied diaphragm technology. The D337 valve is also available with the Rotarex puretec Open/close indicator for an improved safety.

Car(s) Check Valves - HP & UHP Gas Valves by Southern CGS

High-Performance Check Valve for cryogenic gases and liquids

Car(s) Check Valves

Low to high pressure check valves. Operating range -196°C to +250°C cryogenic.

D387 Pneumatic actuator Low Pressure 8mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGSD387 Pneumatic actuator Low Pressure 8mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D387 Pneumatic actuator Low Pressure 8mm orifice valve

D387 low pressure pneumatic cylinder valve for UHP, corrosive, reactive and toxic gases is designed with the tied-diaphragm in order to keep the highest level of purity of the gas. Its 8mm orifice size allows a high CV value.

D342 Dual Port UHP valve Soft seat 8mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGSD342 Dual Port UHP valve Soft seat 8mm orifice valve - Ultra high purity tied diaphragm seal type by Southern CGS

Ultra high purity tied diaphragm seal type

D342 Dual Port UHP valve Soft seat 8mm orifice valve

D342 low pressure valve for Ultra-High Purity corrosive, reactive and toxic gases is designed for keeping the highest level of purity of the gas, thanks to the tied diaphragm technology. The D342 dual ported valve has two outlets marked “LIQUID” to withdraw liquid phase and “VAPOR” for gas phase.

Laboratory regulators (Rotarex)

3 products

Rotarex publishes full technical documentation for every product; the datasheet link on each page goes to it. For applications outside the ranges above, or for Rotarex products not yet listed here, contact us with the model number and we will quote it.

Rotarex technical documentation

Common questions

What is the difference between the RX series and the S series?
They sit at opposite ends of the range. The RX regulators are the ultra high purity units, built and packaged so that the regulator adds nothing to the gas it controls, for semiconductor, analytical and pharmaceutical work. The S series are in line and point of use regulators for laboratory and process supply at working pressures. The purity grade of your gas decides between them, not the pressure.
How can I tell that a Rotarex part is genuine?
Buy through an authorised distributor, and read the markings on the part itself. Rotarex cylinder valves carry the valve number and the date of manufacture alongside the transportable pressure equipment symbol, so a valve can be identified from the valve rather than from its box. If you have a part you are unsure about, send us a photograph of the markings and we will tell you what it is.
Can a Rotarex product be supplied to a special specification?
Often, yes. Several ranges are built to order by outlet standard, seat material, body material and actuation, and the cylinder connectors in particular are made to the standard and the gas you name. Describe the application rather than quoting a part number, and we will find out what is available, including versions that are not shown on this site.

Not sure what you need?

Send us the gas, the pressure and the connection and we will come back with the right unit.

Contact Us